Sunday, March 15, 2020

amateur soccer field lighting design


Football is a highly antagonistic collective sport, which is popular all over the world. The history of football development is enough to show its vitality and influence. According to the regulations of FIFA, the football field is 105-110m long and 68-75m wide. There should be no obstacles within 5m outside the baseline and sideline of the field to ensure the safety of the players. Football lighting is divided into indoor football field lighting and outdoor football field lighting. Different ways of installing lights in different places are also different. The standard should be determined according to the use function of the football field. It can be divided into seven levels: 200lx for training and entertainment activities, 500lx for amateur games, 750lx for professional games, 1000lx for general TV broadcasting, 1400lx for large-scale international games and 750lx for TV emergency. In the past, the traditional football field generally used metal halide lamps or projection lamps with 1000W and 1500W lamps. Because of the shortcomings of traditional lamps, such as glare, high energy consumption, short life, inconvenient installation, poor color rendering and insufficient actual brightness, it has been difficult to meet the lighting requirements of modern stadiums.


Lighting standard for amateur football field(Non TV living)

level
Professional tournaments
amateur tournaments and training
training and entertainments
AVE LUX
500lux
200lux
75lux
UNIFORMITY (u2)
0.7
0.6
0.5
UGR
<50 font="">
<50 font="">
<50 font="">
COLOR TEMPERATURE
>4000k
>4000k
>4000k
RA
80
70
70



Lighting standard for professional football field (TV live)

level international match HD TV Temporary TV live
AVE LUX 1500~3000lux 1500~3000lux 1000~2000lux
UNIFORMITY (u1) 0.6 0.6 0.6
UNIFORMITY (u2) 0.8 0.8 0.8
UGR <50 font="">
<50 font="">
<50 font="">
COLOR TEMPERATURE >4000k >4000k >4000k
RA 80 80 80


A. Light layout in amateur football field: 4 corners outside the field

position of the lamp post



height of posts: 

1. To create uniform lighting, the installation height of the luminaire shall be based on the boundary that can project to the illumination range of the adjacent lamp pole

2. to get lowest UGR, The angle between the center of the court and the lamppost shall not be less than 25 degrees 





Installation position of side lighting system lamp postAt least 10 degrees on both sides of the goal line, giving the goalkeeper a clear view from the target to the corner flag







Installation height of side lighting lamps
The angle between the lamp and the corresponding point of the centerline of the field shall not be less than 25 degrees


B: The light layout in professional football field:Light belt arrangement to create good visual conditions for corner players and goalkeepers, The lamps should not be placed within 15 degrees of the center point of the bottom line of the goal.


solution 1: The lamp pole is installed at the four corners of the field, with a height of 15-20 meters. Each pole is equipped with 5pcs 720W professional stadium lamps


solution 2: The lamp pole is installed at the edges of the field, with a height of 15-20 meters. Each pole is equipped with 5pcs 720W professional stadium lamps


solution 3: 6pcs lamp poles are installed at the edges of the field, with a height of 12-18 meters. Each pole is equipped with 3pcs 720W professional stadium lamps






















We provide professional light distribution support
We have advanced photoelectric testing platform, introduced experimental equipment such as a distributed photometer, photochromic and electrical testing system, which can complete the test of IES file output, light distribution curve, color rendering index, color temperature and other LED light distribution performance data measurement, and provide customers with comprehensive LED optical technology solutions. With professional LED optical engineer and lighting engineer team, we can provide engineering light distribution support, LED optical testing, data collection, sorting, etc. according to customer needs.
Our LED stadium lights (high pole lights)
It adopts high-power citizen cob LED, with excellent heat dissipation performance, it has a variety of professional light distribution options, built-in high-purity aluminum reflector to effectively suppress glare and spillover light, no need to add a protective cover, high-pressure cast aluminum shell, strong anti Strike ability. the overall electrophoresis process, through 200 hours of salt spray test, protection grade IP67.

Related cases:






































Our LED arena lights for soccer field/football field


960W LED arena light

720W LED arena light

480w LED arena light





































to get to know more about us and our products, please contact us!

Mr. Haibo Wen (Sales&marketing Manager)
Email: sales@solaronlamp.com  Alt: hypauwen@solaronlamp.com
Cellphone: 0086 15914113316 web: www.ledsunergy.com
Tel: 0086-755-29588922ext 777 Fax: 0086-755-29588933
MSN&SKYPE: hypauwen@hotmail.com,  hypauwen

No comments: